Driver News: Ness/Elk M1 Security Panel
Jan 31, 2012
Our Ness/Elk M1 driver for Control4 offers full integration with the security panel so that you can expand your automation features to new levels. For example having your system trigger off diferent lights or music depending on the person who disarmed the system or perhaps displaying a message on your security keypad to remind you to pick up the kids from school. The possibilities are endless.

Features
- TCP/IP or RS232 control
- Virtual Keypad Functionality - Arm Stay, Stay Instant, Away, Night, Disarm F1, F2, F3, F4
- Zone Feedback for all zones - Including Normal, Trouble, Violated and Bypassed (Open, EOL, Short)
- Area Feedback for all 8 areas - Including Area feedback for Arming,Disarming and Alarm Feedback
- Output Control and Feedback for all outputs
- Username Feedback for last person who armed/disarmed
- Function Button Feedback
- Invalid User Code Feedback
- Trouble State Feedback
- Telephone Line events
- Remote / Local M1 Programming changes event
- RF Keyfob button press events
- Print all usernames to lua output window feature
- Ability to Activate M1 Tasks
- Ability to trigger spoken words
- Ability to trigger spoken phrases
- Ability to trigger emails via M1XEP
- Ability to trigger zones
- Ability to display text on Ness Keypads
- Auto Setup Zones
Usage Scenarios
- Triggering lighting on motion detection.
- Disarming your security system remotely and unlocking your door to let an unexpected guest in.
- Triggering the favourite music playlist for the person who disarmed the system
- Emailing the username for the person who disarmed the system (requires 4sight)
- Displaying reminders on the M1 keypad
- Pressing the F1,F2,F3 or F4 buttons to turn on/off your lights
- Pressing M1 keyfob buttons to turn on/off lights, open doors, gates or play music.
- Notification of phone line dial out, ring, on/off hook
- Notification of burgular, medical, police, aux1/2 24hr, carbon monoxide, emergency, freeeze, gas, heat or fire alarms.
FREE motion detector driver included. This driver will execute 'Starts Sensing Motion', 'Stops Sensing Motion' and 'Timer Expired' events. The timer is killed when it starts sensing motion. Once the driver stops sensing motion it will start the timer. Once the timer expired it will fire the 'Timer Expired' event. This simplifies programming if multiple occupancy based programming is required.
Note that this driver will not populate the Control4 navigator. If you require a motion sensor proxy then a Control4 motion sensor driver will need to be added and binded to the same Zone connection as the Recluse AV motion sensor driver.